Copper Wire Mesh

Copper Wire Mesh

Material: pure copper proportion 99.9%.
Weaving style: plain weave, twill weave, dutch weave.
Hole shape: square, rectangle.
Width of copper mesh/cloth: 0.5-3 m (can be customized).
Length of copper mesh/cloth: 30 m (can be customized).
Send Inquiry
Description
Technical Parameters

Copper wire mesh is woven from high-copper wire and is selected for electrical and thermal conductivity, ductility, filtration, screening, shielding and decorative appearance.

 

CHG Metal supplies plain-weave copper mesh in different mesh counts, wire diameters, roll widths and sheets, with cutting, punching, bending and hemming available. Copper oxidises in air, so the required colour and surface protection should be defined before ordering.

 

Copper Wire Mesh supplier

Copper Wire Mesh mesh type

 

Copper mesh and copper wire cloth specification

 

 

Product code

Mesh/inch

Wire diameter

Opening

Open area

SWG

inch

mm

CMCS-215

2

15

1.80

0.071

10.90

CMCS-216

2

16

1.60

0.063

11.10

CMCS-316

3

16

1.60

0.063

6.866

CMCS-416

4

16

1.60

0.063

4.75

CMCS-418

4

18

1.20

0.047

5.15

CMCS-420

4

20

0.91

0.036

5.44

CMCS-422

4

22

0.711

0.028

5.64

CMCS-520

5

20

0.91

0.036

4.17

CMCS-621

6

21

0.80

0.031

3.433

CMCS-622

6

22

0.711

0.028

3.522

CMCS-822

8

22

0.711

0.028

2.46

CMCS-823

8

23

0.610

0.025

2.565

CMCS-824

8

24

0.511

0.022

2.616

CMCS-826

8

26

0.457

0.018

2.7

CMCS-1023

10

23

0.610

0.025

1.91

CMCS-1024

10

24

0.511

0.022

1.98

CMCS-1025

10

25

0.508

0.020

2.032

CMCS-1027

10

27

0.417

0.016

2.1

CMCS-1224

12

24

0.511

0.022

1.52

CMCS-1226

12

26

0.457

0.018

1.66

CMCS-1425

14

25

0.508

0.020

1.30

CMCS-1426

14

26

0.457

0.018

1.357

CMCS-1427

14

27

0.417

0.016

1.397

CMCS-1629

16

29

0.345

0.013

1.243

CMCS-1630

16

30

0.315

0.012

1.27

CMCS-1826

18

26

0.457

0.018

0.98

CMCS-1830

18

30

0.315

0.012

1.096

CMCS-1831

18

31

0.295

0.010

1.16

CMCS-2027

20

27

0.417

0.016

0.86

CMCS-2030

20

30

0.315

0.012

0.955

CMCS-2031

20

31

0.295

0.010

1.02

CMCS-2032

20

32

0.274

0.009

0.88

CMCS-2230

22

30

0.315

0.012

0.840

CMCS-2232

22

32

0.274

0.009

0.88

CMCS-2428

24

28

0.35

0.014

0.71

CMCS-2430

24

30

0.315

0.012

0.743

CMCS-2433

24

33

0.254

0.008

0.8

CMCS-2631

26

31

0.295

0.010

0.682

CMCS-2831

28

31

0.295

0.010

0.612

CMCS-3029

30

29

0.345

0.013

0.52

CMCS-3032

30

32

0.274

0.009

0.573

CMCS-3033

30

33

0.254

0.008

0.64

CMCS-3034

30

34

0.234

0.007

0.613

CMCS-3233

32

33

0.254

0.008

0.540

CMCS-3434

34

34

0.234

0.007

0.513

CMCS-3634

36

34

0.234

0.007

0.472

CMCS-3835

38

35

0.213

0.005

0.455

CMCS-4031

40

31

0.295

0.010

0.38

CMCS-4036

40

36

0.193

0.008

0.442

CMCS-4038

40

38

0.152

0.0060

0.485

CMCS-4236

42

36

0.193

0.0076

0.412

CMCS-4437

44

37

0.173

0.0068

0.404

CMCS-4637

46

37

0.173

0.0068

0.379

CMCS-4837

48

37

0.173

0.0068

0.356

CMCS-5032

50

32

0.229

0.009

0.28

CMCS-5034

50

34

0.234

0.007

0.32

CMCS-5037

50

37

0.173

0.0068

0.335

CMCS-5039

50

39

0.132

0.0052

0.378

CMCS-6036

60 × 50

36

0.193

0.0076

-

CMCS-6037a

60 × 50

37

0.173

0.0068

-

CMCS-6033

60

33

0.191

0.0075

0.23

CMCS-6037b

60

37

0.173

0.0068

0.250

CMCS-6040

60

40

0.122

0.0048

0.301

CMCS-6042

60

42

0.10

0.0040

0.32

CMCS-7039

70

39

0.132

0.0052

0.231

CMCS-7041

70

41

0.112

0.0044

0.251

CMCS-8035

80

35

0.213

0.005

0.18

CMCS-8036

80

36

0.193

0.008

0.22

CMCS-8040

80

40

0.122

0.0048

0.196

CMCS-8042

80

42

0.102

0.004

0.216

CMCS-9041

90

41

0.112

0.0044

0.170

CMCS-9043

90

43

0.091

0.0036

0.191

CMCS-10036

100

36

0.193

0.008

0.15

CMCS-10042

100

42

0.102

0.004

0.152

CMCS-10043

100

43

0.091

0.0036

0.164

CMCS-10046

100

46

0.061

0.0024

0.198

CMCS-12043

120 × 108

43

0.091

0.0036

-

CMCS-12044

120

44

0.081

0.0032

0.131

CMCS-12045

120

45

0.071

0.0028

0.14

CMCS-14045

140

45

0.071

0.0028

0.11

CMCS-14046

140

46

0.061

0.0024

0.120

CMCS-14546

145

46

0.061

0.0024

0.1168

CMCS-15046

150

46

0.061

0.0024

0.108

CMCS-16046

160

46

0.061

0.0024

0.098

CMCS-18046

180

46

0.061

0.0024

0.081

CMCS-18047

180

47

0.051

0.002

0.090

CMCS-20047

200

47

0.051

0.002

0.076

 

Conductivity and Shielding

 

Copper mesh is used in heat transfer, electrical contact and some electromagnetic-shielding applications. The woven structure provides flexibility and air permeability.

 

Shielding performance depends on aperture, seams, grounding and frequency, not only on copper content. Provide the frequency and installation details for a meaningful review.

 

Oxidation and Chemical Contact

 

Copper darkens naturally in air, and moisture, sulphur and chlorides accelerate the change. A protective coating may help appearance, but it must not block the mesh or contaminate the filtered medium.

 

Copper is not suitable for strong acids, strong alkalis or ammonia without a specific compatibility review. Food and drinking-water projects also require an alloy and surface review.

copper wire mesh supplier

12

Filtration or Decoration

 

Filtration requires aperture, open area, flow and cleaning data. Decoration focuses on colour, surface, flatness and installation. The same mesh may need different inspection criteria for each use.

 

CHG Metal supplies rolls, sheets, discs and fabricated parts. Approve colour, oxidation, aperture and edge condition on the first article.

 

A copper wire mesh roll can be quoted for filtration, shielding or decorative use. For fine copper mesh and copper mesh for filtration, state the target aperture, surface condition and whether electrical conductivity is part of the requirement.

 

Copper Mesh Inspection

 

Checks cover copper grade, wire diameter, mesh count, aperture, open area, colour, oxidation, surface and width. Shielding or conductive parts can add resistance and grounding checks.

 

Moisture-resistant and scratch-resistant packing is used to control oxidation and deformation.

 

FAQ

Q: Does copper mesh darken over time?

A: Yes. Natural oxidation changes the colour. Anti-oxidation treatment and an acceptable colour range can be specified.

Q: Can copper mesh provide EMI shielding?

A: It can be used in some shielding applications, but performance depends on aperture, seams, grounding and frequency.

Q: Is copper mesh suitable for strong acids?

A: Usually not. Strong acids, alkalis and ammonia require a different material review.

Request a Quote

 

Send the copper mesh count, wire diameter, aperture, dimensions, application, surface, medium and quantity to CHG Metal for a quotation.

Contact now

 

 

 

 

 

Hot Tags: copper wire mesh, China copper wire mesh manufacturers, suppliers, plastic screening fabric, wire fabric, gas filter mesh, kevlar screening mesh, square fabric, granule screening fabric

Send Message